ENGINEERING CALCULATORS

Free sizing and selection tools for SuperKlean washdown systems. Calculate steam consumption, blended water temperatures, pipe pressure drop, and nozzle flow rates — in Imperial or Metric units.

Input

°F
°F
psi
psi

Result

gal/min
pound/h

SuperKlean 8000 Series — Based on factory lookup tables and enthalpy mixing equations. Results are estimates; consult Northeast Controls for precise sizing.

Input

°F
°F
°F
gal/min

Result

gal/min
gal/min

Uses the blending equation: Qhot/Qtotal = (Ttarget − Tcold) / (Thot − Tcold). Assumes equal specific heats.

Input

gal/min
in
ft

Result

ft/s
ft H₂O
psi

Hazen-Williams equation for turbulent water flow. Does not include fitting losses — add 10–20% for elbows, tees, and valves. Recommended velocity: 2–8 ft/s (0.6–2.4 m/s).

Input

psi

Result

gal/min

Flow equation: Q = Cv × √ΔP. Cv values are based on SuperKlean published flow tables. Actual flow may vary ±5% depending on hose length and fittings.

ABOUT THESE TOOLS

These calculators use published SuperKlean factory data and standard engineering equations (enthalpy mixing, Hazen-Williams, orifice flow) to provide sizing estimates.

Results are for preliminary sizing only. Contact Northeast Controls for final system design and certified calculations.